Automatic defroster

At a room temperature under 20 °C not only condensation
water is generated on the cold evaporator surface, but also ice.
This ice blocks the heat exchanger so that the air flow is
impeded. The built-in automatic defroster removes the ice from
the evaporator. This allows a dehumidification operation down
to a temperature of +5 °C.
During defrosting, the
compressor continues to run, the fan is automatically stopped.
Once the defrosting process is finished the air dehumidifier
returns to the dehumidification mode and the

Operating hour counter

The air dehumidifier is equipped with an
operating hour counter.
The number of hours during which the device was in operation
in the past is displayed after the dehumidifier is turned on. The
amount of time during which the device remains on will be
added to the already elapsed time.
W
W
The water collecting container of the air dehumidifier is
equipped with a float switch which turns off the device when the
collecting container is full.
After 45 seconds, compressor and fan will automatically
stop, and an acoustic signal will sound. The
the fault code E4 will be displayed.
Another acoustic signal will sound every 5 minutes if the
water collecting container is not immediately emptied.

Removing the water collecting container

1. Turn off the device.
2. Open the enclosure door.
3. Remove the container (8) and empty is immediately.
4. Re-insert the container. Make sure that the container is
correctly positioned.
5. Close the hinged enclosure cover.
6. Restart the air dehumidifier. The
E4 should no longer be displayed.
Icon and fault code are further displayed? Remove the
container again and re-insert it properly.
icon is displayed on the display, the
icon turns off.
a
t
e
r
o
u
t
l
e
t
a
t
e
r
o
u
t
l
e
t
icon and the fault code
In the case of a high humidity of air it is recommended to
operate the air dehumidifier in continuous mode. In continuous
mode it is not needed to empty the water collecting container.
Proceed as follows:
1. Remove the water collecting container from the device.
2. Remove the stopper (9).
3. Re-insert the collecting container in the device.
4. Guide the hose (14) through the housing. Push the hose on
the water drain nozzle (a).
icon and
Pay attention to the following:
Make sure that the water can flow out unhindered.
Pipe the water preferably to a drain which is positioned at
a lower level.
Make sure that the hose remains in its position, is routed
with a descending gradient, is not kinked or wound up.

Continuous or extended operation

19