EN
Mount at door
Note:
make sure the detection direction faces towards the interior, no matter it is installed
on wall or at ceiling. Adjust the bracket angle to optimize the detecting effect.
Avoid mounting the detector close to air conditioner, electronic fan, refrigerator, oven,
heater and objects which will cause fast temperature changing, and avoid mounting it
under direct sunlight.
Detection Scope
Testing (Walk Test)
After installation, press the test button, walk in the scope by
crossing the infrared spectrum (see below diagram), and watch the
once when body movement is detected.
Connect with the Control Panel
When the control panel is in connecting state, press the test button
on the detector twice to send wireless signal. One beep is heard
after panel receives signal, which means of successful connection.
Arm the system, trigger the detector again. The panel will alarm
immediately. This indicates the detector has been successfully
connected with the panel.
Note:
Make sure other detectors are not triggered while connecting.
EN
High detection sensitivity
Low detection sensitivity