LIGHTING, OPERATION, AND SHUTDOWN
INSTRUCTIONS
1. Make sure the control knob is in the OFF position. " "
2. Open the access door and install the propane fuel source;
a. Install a DOT certified 1 lb. propane cylinder.
b. Install the GHP hose connector model #
Check for gas leaks by using a 50% soap-water solution
at the joint of the regulator and cylinder.
3. Depress the control knob and turn counter clockwise to the
PILOT position. " " The Igniter will spark each time this
step is performed. Repeat until the pilot flame lights.
4. Continue holding the knob down in the PILOT position for
30 seconds or until pilot flame holds.
5. Release the knob. The knob should return to the fully
extended position and the pilot should remain lit.
6. Turn on the burner by depressing the knob slightly and
gently turn the knob to the HI position " ".
7. Adjust heat output by turning the knob between HI and
LOW position " ".
8. To shut down the heater turn the knob clockwise to the OFF
position and remove the gas cylinder or close the propane tank
shut off valve and allow the heater to burn off the gas in the
hose, then turn the heater knob to the OFF position. Always
wait 5 minutes before relighting heater.
CAUTION
Do not try to adjust heating levels by using the propane tank shutoff valve.
After turning heater off the guard will remain hot. Allow the heater to cool
down before storing the heater.
Do not operate, store, connect or remove cylinder/hose connection near
flammable items or ignition sources.
LIGHTING / OPERATING INSTRUCTIONS FOR
USE WITH HOSE(S) CONNECTED TO A REMOTE
CYLINDER, MAXIMUM SIZE 20 LBS:
• GHP Hose No. HAKITDG includes a hand-tightening tank connector
with a CGA regulator and a #600 hose connector fitting.
•
WARNING: NEVER bring a refillable propane cylinder indoors. A
fire or explosion can occur causing property damage, serious injury
or death!
• Inspect the hose before each use of the heater. If there is excessive
abrasion or wear, or the hose is cut, replace prior to using the heater
with Dyna-Glo HAKITDG.
• The propane cylinder must include a listed overfilling protection
device as well as a collar to protect the cylinder valve.
• Heater must be in an upright position during operation.
• Screw hose connector into tank swivel on heater and screw opposite
end of hose into LP gas tank valve. Tighten all hose connections. DO
NOT use thread sealant on any of these connections.
• Open valve at LP-gas supply cylinder.
• Check all hose connections for leaks with soapy water at the
threaded connection where the hose connector screws into the
regulator and at LP-gas supply cylinder. SEE WARNING! ON
ATTACHED HANG TAGS.
LIGHTING IN WINDY AREAS
1. Position the heater such that the Pilot is opposite the direct that the
wind is coming from.
2. Position your body behind the heater such that your body blocks the
wind while you are following the instructions for lighting the unit.
HAKITDG.
6
Pilot Position
HIGH Position
LOW Position
Fig. 2 - Lighting Instruction
Fig.
-Lighting Instructions
WIND DIRECTION
Fig. 3 - Lighting in Windy Areas
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Knob Indicator Mark
OFF Position
Control Knob
PILOT POSITION