General Information; Cold Weather Operation - Dyna-Glo HeatAround360 ELITE HA2360R-01 Guide De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GENERAL INFORMATION:

• This heater is for outdoor and temporary indoor use in a well ventilated area. DO NOT USE IN A BEDROOM OR BATHROOM.
• This heater requires a vent area of 18 square inches (example 4 1/4" X 4 1/4" opening) or 118 suare centimeters (example 11 cm X
11 cm opening) minimum for adequate ventilation during operation. Do not use other fuel burning appliances inside.
• When the heater is cold or at room temperature, it will take a few minutes for the burner to turn bright orange. This is normal and the
heater is working properly. Also, during the initial lighting, the oil used during manufacturing process needs to burn off. This can take up to
60 minutes of continuous burning. Some odor and yellow flames may occur during this time but will diminish after the burn-in period.
• After a few hours of operation the upper burner plate will discolor due to the heat of normal operation. This is normal and does not affect
the safe operation of the unit.
• It is recommended not to use the heater in windy conditions. The heater may flutter reducing the effectiveness of the appliance
and could have excessive pilot outages.
• When the unit is lit, there should be about a quarter inch border that will not turn bright orange. This is normal.
• When operating the heater at altitudes over 7,000 FT. above sea level, the unit may not burn as bright as in lower altitudes.
This is normal. At higher altitudes, the heater may shut-off. If this happens, provide fresh air, wait 5 minutes and re-light.
Due to local atmospheric conditions heater may not re-light.
• When moving heater when lit or bumping heater setting it down, tip over switch may shut off heater. If this happens, re-light.
• Operating time will vary depending on the heater setting and the supply cylinder size. See chart and "Cold Weather Operations"
section.
• NOTE: THIS HEATER MAY BE OPERATED WITH (2) DISPOSABLE 1 LB. PROPANE CYLINDERS OR WITH (1) REMOTE
REFILLABLE PROPANE CYLINDER MAX. 20 LBS USING BOTH (1) Dyna-Glo Model # HAKITDG 12' Extension Hose and
(1) Dyna-Glo Model # HAKITDG Fuel Filter (Sold Separately)

COLD WEATHER OPERATION:

• Cold weather is generally defined as ambient temperatures below 32 degrees F.
• 1 lb. propane cylinders have difficulty producing sufficient gas at lower temperatures and can "freeze-up", reducing the time of
operation by as much as 50-70%. For this reason, it is recommended to use only 20 lb. propane tanks under these conditions.
• If a 1 lb. tank is used in cold weather, following are some operating suggestions;
1. Expect operating times to be significantly reduced.
2. Never use only a single 1 lb. tank on the Heat Around Elite unit, Model HA2360.
3. Never set the heater directly on the ice. Set the heater on a rigid piece of flame retardent insulation and make sure the
ventilation slots on the bottom of the heater are not obstructed.
4. Elevate the heater slightly above the ground level. Insure the unit is level and secure and cannot be knocked over.
5. Keep the tank access door open. This provides some additional heat to warm the 1 lb. cylinder.
6. Adequate ventilation and combustion air must be provided.
7. Maintain all clearances as specified on Page 4.
Carefully watch the Heater for signs of the 1 lb. cylinder "freezing-up". If the lower portion of the burner starts to turn from
orange to blue and begins sputtering immediately shut off the heater and remove it from any enclosure.
WARNING:
3
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!