Type:
Power supply:
Max. rated power of motor:
Weight:
Dimensions:
Class of protection:
Connection plan
Technical data
S50 II
3 x 400/230V 50/60 Hz (L1, L2, L3, N, PE)
1.8 KW
1.3 kg
182 x 180 x 90 (W x H x D)
IP 54 (IP 65 optional), for indoor use only
S1F.
Safety.limit.switch.OPEN
S2F.
Safety.limit.switch.CLOSED
SF.
Safety.limit.switch.emergency.activation
S4F.
Thermal.switch
S5.
Operating.limit.switch.OPEN
S6.
Operating.limit.switch.CLOSED
S7.
Testing.pre-limit.switch
S8.
Special.function.limit.switch.1/2.door.height
LED.OPEN.
Display.for.ascent
LED.CLOSED. Display.for.descent
LED.+UB.
Display.for.operating.voltage
FS1=A.
Relay.actuation.by.Mutlicard.II
FS1=B.
Relay.actuation.by.limit.switch.S8
/1.
UP.command
/2.
DOWN.command. external.triple.pushbutton
/4.
STOP.command
5/6.
Emergency.stop.switch
7/8.
USA./.Closing.edge.safety.device.(SKS)
11/12.
IMP./.Switch.for.step.switching.sequence
9/10.
LS./.Light.barrier
1/14.
WZL./.Switch.for.automatic.reclosing
F2-250mA.T.
Fuse.for.control.electrics
DE
GB
FR
NL