Operating Instructions
Possible.faults:
S50II.does.not.switch.on.when.the.
power.supply.is.switched.on..+UB.
pilot.light.(green).on.the.mother-
board.does.not.illuminate.
No.response.when.buttons.are-
pressed.
The.door.only.closes.in.
deadman's.mode,.although.the.
"Multicard.II".with.safety.edge.is.
being.used.
The.door.only.opens.in.
deadman's.mode.
14
What should you do, if...?
Possible.causes.and.remedy:
-. Check.mains.feed.(fuse).
-. Check.safety.circuit.(e.g..emergency.stop.switch,.slack.cable.limit.switch,.safety.limit.
switch).
-. Check.that.connection.wires.are.securely.fi . xed.in.the.terminals.
-. Check.fi . ne-wire.fuse.inside.the.unit..Replace.if.defective..If.failure.occurs.again,.inform.
your.dealer.
-. Check.emergency.stop.circuit.
-. Check.safety.circuit.
-. Check.plug-in.connections.of.triple.pushbuttons.
-. Check.safety.edge.
-. Check.integrated.loop.resistance.and.DIP.2.switch.position.(1.2.kOhm.or.8.2.kOhm).
-. Check.pneumatic.setting.
-
Please also note the relevant error codes of the "Multicard II".
If.the.deadman's.card.is.being.used:
-. Sliding.switch.on.deadman's.card.is.set.to."Deadman.UP".
If."Multicard.II".is.being.used:
-. Card.is.in.setting.mode..Check.the.setting.of.DIP.switch.8.
Wiring diagram