5.1.3.1 Configuration of machine voltage.
The voltage configuration of the machine is stipulated on the nameplate (230V 1N~50Hz/60Hz). This
configuration cannot be changed, therefore it is essential that the mains voltage of the premises
where the machine is to be installed is confirmed prior to purchase.
asberprofessional.com
35
The electric cable should be flexible, with an oil-proof covering, and it should not weigh less
than the cable in an ordinary sleeve made of standard polychloroprene or an equivalent syn-
thetic elastomer (H05RN-F).
The machine you have purchased is supplied with a power cable suitable for the electrical
specifications of the machine.
An easily accessible switch device should be installed next to the appliance for all the phases,
with a minimum gap of 3 mm between contacts. This switch should be used to disconnect the
appliance during installation, repair, cleaning and maintenance work. The switch should have
fuses suitable for use with the rated current (A) of the machine. Alternatively, a suitable mag-
neto-thermal switch may be used.
The appliance must be earthed using a differential protector. The manufacturer will not be
held liable for damage originated by failure to observe this requirement.
If any faults are observed during the installation, the supplier should be notified immediately
for the subsequent analysis of the machine.
THE MANUFACTURER WILL NOT BE HELD LIABLE FOR ANY PERSONAL
OR MATERIAL DAMAGE TO THE MACHINE RESULTING FROM THE
INCORRECT INSTALLATION ORIGINATED BY FAILURE TO COMPLY WITH
THE MANUFACTURER'S SPECIFICATIONS.
Figure 11. 230 V 1N Connection
a = azul / bleu / blue / blau / blu
m = marrón / brown / braun / marrone
r = rojo / rouge / red / rot / rosso
n = negro / noir / black / Schwarz / nero