10.

Aurelia V MACHINE FUNCTION MESSAGES

DISPLAY AND KEY
INDICATIONS
+
+ ECC
66
CAUSE
If the doser doesn't send
If the delivery is not hal-
out its commands within
ted manually, the time
three sec from the onset
limit (120 sec.) will be
of delivery.
blocked.
If within 90 sec. from
The pump, the resistor
onset, with pump inser-
and all the functions will
ted during the levelling,
be halted.
at 180 sec., if the level
has not been re-establis-
hed.
EFFECT
SOLUTION
Interrupt the delivery.
Turn the machine off for
at least 5 sec. and then
switch it on again.