5.3 Connection with the mains
Connect the device to the mains with the power plug.
The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
5.4 Outputs
Output is via 4 safety sockets on the rearpanel.
Connect your loads via the output-sockets. The maximum load per channel is 1,150 W (resistive) or 600 W
(inductive). Please note that the maximum current of 16 A must never be exceeded.
The occupation of the 6-pin industrial socket is:
6. OPERATION
After you connected the device to the mains, the LCD-4 MP/S is ready for use.
6.1 Hold-Dimmer Mode
Call spots manually:
In the Hold Dimmer Mode, the connected spots can be called manually and be controlled via the channel
faders.
Adjust the desired function via the channel faders.
1. Turn controller ON
2. Press Mode Select until Hold Dimmer LED is illuminated
3. Adjust channel faders
4. Adjust dimmer fader for total output
This function is useful for theatres and booth illumination.
6.2 Hold-Sound Mode
Spots as light organ:
International
L
N
17/36
00026201.DOC, Version 2.3