MAINTENANCE

To eliminate unnecessary wear and improve lifespan, disconnect the LEO™ LED Follow Spot completely from power when
not in use.

TO EXTEND LED LIFESPAN

• Keep unit clean and vent holes clear from debris
• Maintain adequate ventilation around the fixture while in use
• Reduce ambient temperature
• Limit overall projection intensity

LENS CLEANING

• Unplug LED Follow Spot from power and wait until fixture is at room temperature
• Open lens compartment door by lifting the two spring clips on the top of the lens tube
• Remove dust with a blast of oil-free air or wipe with a clean, lint-free cloth
• DO NOT use ammonia-based or other harsh commercial cleaners (Isopropyl alcohol may be used on the cloth)
• Ensure all parts are completely dry before restoring power
• Replace lenses if they contain visible damage (cracks or deep scratches)

FUSE REPLACEMENT

• Unplug the product from power.
• Using a slotted screwdriver, push slightly at the slot of the fuse cap and rotate
counterclockwise to open.
• Remove fuse cap and fuse. Place new fuse inside the fuse cap.
• Screw the fuse cap with new fuse back in place and reconnect power.

ACCESSORIES

To eliminate unnecessary wear and improve lifespan, disconnect the LEO™ LED Follow Spot completely from power when
not in use.
Accessory
Drop-In Iris
B Size Metal Gobo Holder (W 3-3/4", Open Dia 2-3/4")
5-Color Changer (Black)
5-Color Changer (White)
Follow Spot Tripod
Follow Spot Tripod with wheels
NOTE: LEO™ LED Follow Spot comes with a power lead terminated with a powerCON A connector on one side, and a PBG
NEMA 5-15P connector on the other side. Other connector options are available from Leviton or may be installed by your
contractor.
Connection
AC Live
AC Neutral
AC Ground
Power Cable Color Coding for Inspection
Wire
Brown
Blue
Green/Yellow
6
FUSE
250VAC 5A
SLOW BLOW
OPEN
Part Number
LEDAC-IRS
LEDAC-PTN
N/A - Available with fixture only