Low Oil Shutdown; Do Not Overload Generator; Parallel Operation - Firman W03083 Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Electric Start and Recoil Start Operations
Flip the engine switch to"OFF"(O) position.
4. Turn the fuel valve to the "OFF"(O) position.
If a cover is used, do not install until unit has cooled.
If the engine will not be used for a period of two
weeks or longer, please see the Storage section
for proper engine and fuel storage.

Low Oil Shutdown

If the engine oil drops below a preset level, an
oil switch will stop the engine. Check oil level
with dipstick.
If oil level is between the LOW and HIGH mark on
dipstick:
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is corrected.
If oil level is below the LOW mark on dipstick:
1.Add oil to bring level to HIGH mark.
2.Restart engine and if the engine stops again
a low oil condition may still exist. DO NOT try
to restart the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is
corrected.
English
STOP

Do Not Overload Generator

Overloading a generator in excess of its rated
wattage capacity can result in damage to the
generator and to connected electrical devices.
To prolong the life of your generator and
attached devices, follow these steps to add
electrical load:
1. Start the generator with no electrical load
attached.
2. Allow the engine to run for several minutes
to stabilize.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Overload Operation
The overload indicator light will turn on and cut
power to the receptacles after 30 seconds when
the load exceeds 3080W(approximately).
The overload indicator light will turn on and cut
power to the receptacles after 2 seconds when
the load exceeds 3150W(approximately).
How to Correct
1. Disconnect any electronic devices, and then
stop the engine.
2. Reduce the total wattage of connected
electronic devices until it is within the generator's
rated output.
3. Inspect the Air Inlet and Control Panel for any
blockage. Remove blockage if found.
4. Restart Engine.

Parallel Operation

Any two FIRMAN inverter generator with parallel
port including two FIRMAN inverter model W03083
can be paralleled to increase the total available
electrical power to 5500 Watts. A FIRMAN Parallel
kit (not included) is required for parallel operation.
For Kit availability, call customer Service at
1-844-347-6261 or visit: www.firmangenerators.com.
CAUTION:
DO NOT disconnect parallel cables while generator
is running.
Page 22