Technical Data; Accuracy; Ambient Conditions; Supply Voltage (External) - Balluff BTL7-A/C/E/G5 -M -HB/WB-KA /K Série Notice D'utilisation

Capteur de déplacement micropulse - forme à tige
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BTL7-A/C/E/G5 _ _ -M _ _ _ _ -HB/WB-KA_ _/K_ _/FA_ _/F_ _
Micropulse Transducer - Rod Style
10

Technical data

10.1

Accuracy

The specifications are typical values for the
BTL7-A/C/E/G... at 24 V DC and room temperature, with a
nominal length of 500 mm in conjunction with the
BTL-P-1013-4R, BTL-P-1013-4S, BTL-P-1012-4R or
BTL-P-1014-2R magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Repeat accuracy
Typical
Sampling rate
Dependent on the nominal length
At nominal length = 500 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 to ≤ 5500 mm
Nominal length > 5500 mm
Temperature coefficient
1)
Max. detectable velocity
10.2

Ambient conditions

Operating temperature
Operating temperature for UL
(only BTL7-...-KA...
and BTL7-...-K...)
Storage temperature
Humidity
Rod pressure rating (when
installed in hydraulic cylinders)
Shock rating
Continuous shock
per EN 60068-2-27
3), 4)
Vibration
per EN 60068-2-6
3), 4)
Degree of protection per IEC 60529
Cable
With connected cable
protection system
20
english
±10 µm
250 µs...5.5 ms
500 µs
±50 µm
±0.01% FS
±0.02% FS
≤ 30 ppm/K
10 m/s
2)
–40°C...+85°C
Max. +80°C
–40°C...+100°C
< 90%, non-condensing
< 600 bar
100 g/6 ms
100 g/2 ms
12 g, 10...2000 Hz
IP68
3)
IP69K
3)
10.3

Supply voltage (external)

Voltage, stabilized
5)
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
6)
Overvoltage protection
Dielectric strength
(GND to housing)
10.4

Output

BTL7-A... Output voltage
Load current
BTL7-C... Output current
Load resistance
BTL7-E... Output current
Load resistance
BTL7-G... Output voltage
Load current
Short-circuit resistance
10.5

Input

Programming inputs La, Lb:
BTL7-_5_ _-...
Overvoltage protection
Nominal length = 500 mm, magnet in the middle of the measuring range
1)
For
: Use in enclosed spaces and up to a height of 2000 m above
2)
sea level.
3)
Individual specifications as per Balluff factory standard
4)
Resonant frequencies excluded
For
: The transducer must be externally connected via a limited-energy
5)
circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or UL 1585.
6)
A prerequisite is that no current can flow between GND and 0 V in the
event of polarity reversal.
10...30 V DC
≤ 0.5 V
ss
< 120 mA
≤ 500 mA
Up to 36 V
Up to 36 V
500 V AC
0...10 V and 10...0 V
≤ 5 mA
0...20 mA/20...0 mA
≤ 500 ohms
4...20 mA/20...4 mA
≤ 500 ohms
–10...10 V and 10...–10 V
≤ 5 mA
Signal cable to 36 V
Signal cable to GND
High-active
10...30 V DC
up to 36 V

Publicité