BTL7-A/C/E/G5 _ _ -M _ _ _ _ -HB/WB-KA_ _/K_ _/FA_ _/F_ _
Micropulse Transducer - Rod Style
4
Installation and connection (continued)
Supporting rod made of non-magnetizable material
Fig. 4-8:
Example 2, transducer installed with supporting rod
4.4
Electrical connection
The electrical connection is permanent and made using a
cable. The connection assignments can be found in
Tab. 4-2.
Note the information on shielding and cable
routing on page 11.
4.4.1
Cable connection
Cable color
-A510
YE yellow
not used
GY gray
PK pink
10...0 V
RD red
GN green
0...10 V
BU blue
BN brown
WH white
Unassigned leads can be connected to the GND on the controller side but not to the shield.
1)
Reference potential for supply voltage and EMC-GND.
2)
The voltage outputs may exhibit a minimal offset to the harmonized current output.
3)
Tab. 4-2:
Cable assignment BTL7... cable
10
english
Magnet
(e.g. BTL-P-1028-15R)
-G510
-C500
-C570
0...20 mA
20...0 mA
1)
0 V
10...–10 V
La (programming input)
–10...10 V
GND
2)
10...30 V
Lb (programming input)
-E500
-E570
4...20 mA
20...4 mA
10...0 V
3)
0...10 V
3)