WARNING: Do not attempt to repair the power supply. There are no user serviceable parts.
Symptom
No Power, power
supply indicators
do not light
Cleaner does not
operate
All power supply
indicators flash,
cleaner does not
operate
HAYWARD only warranties the quality, performance and safety of its products when assembled with genuine
Hayward manufactured parts. Use of non-genuine Hayward manufactured parts will void all warranty.
Page 15 of 20
TROUBLESHOOTING - POWER SUPPLY
Make sure that the power supply is plugged into a functioning Residential
Current Device (RCD) protected outlet. Reset the RCD if necessary.
Note: Repeated RCD trips may indicate a faulty RCD or non repairable failure of
the power supply. In such case, discontinue use of the power supply.
Make sure that the service circuit breaker or fuse have not tripped.
It may take up to 1 minute from the start of a cleaning cycle for the cleaner to
begin moving. Make sure that a cleaning cycle has been initiated.
A problem was detected with the power supply. The flash pattern identifies the
type of problem.
*1 flash every 3 seconds: Overcurrent Detection: This may happen if debris
becomes lodged in the impeller or drivetrain of the cleaner. A damaged cleaner cable
is also a potential cause of this issue. This fault can be cleared by unplugging the
power supply from the utility power for at least 1 minute.
*2 flasher every 3 seconds: Over Temperature Detection. The failure will
automatically reset and a cleaning cycle will commence when the power supply cools
down. Place the power supply upright with the heatsink away from a wall or surface.
Keep the power supply out of direct sunlight.
*3 flashes every 3 seconds: Unplug the power supply from the utility power. Wait
at least 1 minute to reset the fault. Make sure the cleaner cord is not plugged into
the power supply. Plug the power supply power cord into the electrical outlet. Set the
power supply to start a cleaning cycle. If this fault repeats, the problem is with the
power supply. Otherwise, there is a problem with the cleaner or the cleaner cord.
Possible Solutions
Rev. C