Maintenance And Cleaning; Setting The Pressure Switch - EINHELL EURO 4000/1 Mode D'emploi

Masquer les pouces Voir aussi pour EURO 4000/1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Anleitung Euro 4000 SPK1
GB
anticlockwise until you can
4
hear compressed air being
blown out. Then turn the
knurled screw clockwise as far
as the stop and tighten by
hand.
● Regular oil level checks
The level of oil has to be visible
in the sight-glass between the
red check-point mark and the
upper edge of the sight-glass.
Changing the oil:
Recommended grade SAE
● Tensioning the V-belt
15W/40 or equivalent.
Pull out the power plug.
The first oil change should be
Remove the V-belt guard.
carried out after 100 operating
Undo the four motor fixing
hours. Thereafter you should
screws and use a wooden
drain the oil and replace it with
wedge between the pump and
new oil at intervals of 500
the motor to lever the motor
operating hours.
toward the rear and tension the
● Changing the oil
V-belt. The V-belt is correctly
Switch off the motor and pull
tensioned if you can depress it
the power plug out of the
approx. 1-2 cm with your
socket-outlet. After letting off
fingers.
any air pressure you can
remove the oil drain plug from
the compressor pump by un-
screwing. To prevent the oil
escaping out of control, hold a
small piece of metal guttering
underneath the drain plug to
direct the oil into a container.
If any oil still remains inside, tilt
the compressor a little.
Take the old oil to an official
old oil disposal station.
Maintenance and
When the old oil has run out,
cleaning
screw the oil drain plug/sight-
glass back in place.
● Condensation water
Use a screwdriver to remove
Let out the condensation water
the cap of the oil filler plug and
daily by opening the drain valve
fill in oil until the level of oil in
(bottom of the pressure
the sight-glass reaches the red
vessel).
mark.
● Safety valve
Then put the cap back on the
oil filler plug.
The safety valve is set to the
maximum pressure of the
pressure vessel. It is prohibited
to adjust the safety valve or to
1 Filter
remove its lead seal.
2 Oil filter plug
To ensure that the safety valve
3 Oil drain plug
works properly in the event of
4 sight-glass
an incident you should actuate
it from time to time. To do so,
turn the knurled screw
12
23.11.2006
14:29 Uhr
Seite 12
5
● Cleaning the intake filter
The intake filter prevents dust
and dirt being drawn into the
machine. This filter has to be
cleaned at intervals of no
longer than 300 operating
hours. A clogged intake filter
has a considerable negative
effect on the compressor's
power.
The filter can be removed as
shown in Figure 3. Wash out
the filter with petroleum ether
and reinsert.
Caution! Wait until the
compressor has cooled
completely!
Risk of burns!
Setting the pressure
switch
The pressure switch is set at the
factory.
Switch-on pressure 6 bar
Switch-off pressure 10 bar
6