Feeding In The Wire En; Risk Of Injury - Abicor Binzel ABIDRIVE CW Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5 Putting into operation
5.7 Feeding in the wire

Risk of injury

Bodily harm caused by the beginning of the wire.
• Keep cold wire feed at the torch head away from the body.
1
2
3
Fig. 6
1 Open cover at the ABIDRIVE CW .
2 Fold pressure lever (1) forward and open pressing rolls (2) .
3 Untie beginning of wire at the wire spool and debur it at the front end.
4 Insert wire through the liner (3) over the driving rollers (4) into the central socket (5).
5 Close pressing rolls (2) and fold pressure lever (1) into vertical position.
6 Press "Currentless wire feed". Wire is being fed through the cable assembly.
This completes the feeding of the inserted wire.
EN - 12
CAUTION
1
5
Pressure lever
2 pressure rolls
Liner
Feeding in the wire
TIG cold wire feeder
2
3
4
4
2 driving rollers
5
Central socket