TROUBLESHOOTING - Continued
PROBLEM
Poor vacuum recovery.
SPECIFICATIONS
MODEL
LENGTH
WIDTH
HEIGHT
WEIGHT
RECOVERY TANK CAPACITY
SOLUTION TANK CAPACITY
MAXIMUM CLEANING RATE
MAXIMUM SPEED
CLEANING PATH WIDTH
DRIVE SYSTEM
MAXIMUM RATED CLIMB
BRUSH MOTOR
VACUUM MOTOR
WATER LIFT / AIR FLOW
PUMP
TOTAL POWER CONSUMPTION
POWER CORD LENGTH
DECIBEL RATING AT OPERATOR'S EAR,
INDOORS ON CARPET
Specifictions are subject to change without notice.
Tennant 1530 (12- 02)
CAUSE
Recovery tank is full.
Float Shut-off screen inside recovery
tank is clogged.
Pickup vacuum shoe is clogged with
debris.
Loose drain hose plug.
Vacuum hose connections are loose
or hose has a hole.
Clogged vacuum hose.
Recovery tank inlet hole is obstructed.
Recovery tank cover is not in place.
Worn tank cover gasket.
Loose vacuum motor.
Faulty actuator.
1530
1270 mm (50 in)
559 mm (22 in)
1067 mm (42 in)
180 Kg (395 lb)
80 L (21 Gal)
113.6 L (30 Gal)
Surface Clean Mode: 1022 m
Deep Clean Mode: 511 m
Surface Clean Mode:30 m (100 ft) per minute
Deep Clean Mode: 15 m (50 ft) per minute
Travel Mode: 45 m (150 ft) per minute
483 mm (19 in)
120V Transaxle, .19 kw (.25 hp)
5 with full tanks / 9 with empty tanks
120V, .25 h.p., 1800 rpm, 2800 brush rpm, 1.5 A, 186W
120V, 1.63 h.p., 3- stage 5.7 in, 10A. 1200W
2972 mm (117 in) / 99cfm (2.80m
120V, 6.9 bar (100 psi), 3.8 L (1 gal.) per minute.
120V, 14 Amps
23 m (75 ft)
72 dB(A)
OPERATION
SOLUTION
Empty recovery tank.
Remove screen and clean.
Clean pickup vacuum shoe.
Tighten plug.
Push hose cuffs firmly on connections.
Replace hose if damaged.
Remove clogged debris.
Empty recovery tank and tilt tank side-
ways to access inlet hole, remove ob-
struction.
Properly position lid.
Replace gasket.
Contact Service Center.
Contact Service Center.
2
(11,000 sq ft) per hour
2
per hour (5,500 sq ft)
3
) per minute
19