Battery capacity
6,8 Ah
Battery weight
1,40 kg
Docking station ADO 601:
Voltage U
42 V
DC
Protection class
III
Type of protection
IPX1
Weight
3 kg
Power supply unit:
Voltage U
100 - 240 V
AC
Frequency
50/60 Hz
Voltage U
42 V
DC
Protection class
I
Type of protection
IP67
Transport of VIKING batteries:
VIKING batteries meet the requirements
specified in UN manual
ST/SG/AC.10/11/Rev.5 Part III,
subsection 38.3.
The user may carry VIKING batteries to
the place of use of the machine without
further restrictions during road transport.
Country-specific legislation must be
observed in the case of air or sea
transport.
For further transport instructions, see
www.viking-garden.com/safety-data-
sheets
REACH:
REACH is an EC Directive for the
registration, evaluation, authorisation and
restriction of chemicals. For information on
compliance with the REACH Directive
(EC) No. 1907/2006, see
www.stihl.com/reach
0478 131 9937 B - EN
24. Messages
Messages provide information on
active errors, faults and
recommendations. They are
displayed in a dialog window and can be
called up after pressing the OK button in
the "Messages" menu. (
24.)
Recommendations and active messages
also appear in the status screen.
(
11.10)
The message code, the time of
occurrence, the priority and the frequency
of occurrence can be called up in the
message details.
– Recommendations are awarded
the priority "Low" or "Info", they
appear in the status screen alternately
with the text "iMow ready for op.".
The robotic mower can still be
operated, automatic operation
continues.
– Faults are awarded the priority
"Medium" and require action on the
part of the user.
The robotic mower can only be
operated again once the fault has been
rectified.
– In the cases of Errors awarded the
priority "High" the text "Contact
your specialist dealer" appears in the
display.
The robotic mower can only be
operated again once the fault has been
rectified by a VIKING specialist dealer.
If a message is still active despite
the proposed remedial action,
please contact your VIKING
specialist dealer.
Faults that can only be rectified by
a VIKING specialist dealer are not
listed in the following. Should a fault
of this kind occur, please
communicate the 4-digit fault code
and the fault text to your specialist
dealer.
Messages that impair normal
operation are also reported to the
app. (
10.)
The robotic mower enters standby
after the message is sent and
disables radio communication to
preserve the battery.
Message:
0001 – Data updated
Press OK to release
Possible cause:
– The machine software has been
updated
– Voltage loss
– Software or hardware error
Remedy:
– After the OK button is pressed, the
robotic mower operates with the default
settings – check and correct the
settings (date, time, mowing plan)
159