MIG PULSE WELDING WITH
POWER SOURCE - OPTIONAL
MIG PULSE
welding
Welding
current
Wire
speed
Material
thickness
Synergic
welding
curve
Showing the Arc dynamic
when key
Figure 27 - MIG PULSE Display View
1
1
2
MODE
MATERIAL
SETUP
DYN
6
3
Figure 7 - Power Source Control Panel - Copy
Setup Key
3
for entering the parameters' setup screen.
6 8
Navigation Key
for running thru the parameters.
Right Regulation Knob
5
for changing the parameters.
EN-24
Full cycle
Double
2T
Pulse
4T
SPOT
PW
Voltage
(V)
Arc
dynamic
Arc
Voltage
Balance
is pressed.
6/8
7
5
1
2
/A /
V/PARAM.
WORKING POINT
SAVE &
RECALL
8
4
Figure 28 - MIG PULSE Setup View
TRIGGER MODE
Selection of the 2Stroke / 4Stroke / Spot Welding
Mode / Pause-Work Mode (P-W)
SPOT TIME W
Adjustable only when Spot Welding Mode or P-W
Mode is set: regulation of the maximum duration of
the Spot Welding Time (0-25 sec)
SPOT TIME P
Adjustable only when P-W Mode is set: regulation of
the maximum duration of pause (0-25 sec)
WIRE SLOPE
Regulation of time needed to reach wire set speed
after arc striking. Time (0-2.55sec) is adjustable only
with knob inside wire feeder (see control interface
paragraph)
CYCLE
Normal or full
PRE GAS TIME
Regulation of the Gas outflow before the welding
start (0-25 sec.)
HOT START %
Percentage of current increase during hot start phase
HOT START VOLTAGE
Adjust arc voltage compensation during hot start
phase
HOT START TIME
Time of hot start phase