Please read before commencing any operation.
After the removal of all the packaging, carefully open and check the contents of the start up pack (Fig.1).
1
2
Fig.2a
Lift top tank assembly to reveal battery compartment.
Always lift between points as illustrated to ensure personal safety (Fig.1a).
Fit battery fuses (contained in start-up pack) into the battery fuse holders as illustrated (Fig.2).
Remove transit block from pallet (Fig.2a).
Note: Ensure that no metal objects come into contact with battery terminals while the batteries are exposed.
When inserting the first fuse you may notice a spark, this is normal.
3
Insert key (Fig.3) into ignition and turn quarter-turn clockwise to the 'ON' position (1).
Ensure that the forward/reverse switch is set to forward (Fig.4).
Depress accelerator pedal with right foot and slowly drive machine off of the pallet
using the ramp provided (Fig.5).
Note: The seat is fitted with a pressure sensor that disables the machine until an operator
is seated.
When the machine is removed and in a safe position, turn key back to the off position (Fig.6).
Fig.1a
Fig.3
Fig.4
9
Quick Set Up Guide
Contents:
1 x Operator Manual
2 x Keys
3 x 40 amp fuses (1 x spare)
2 x Side pod skirts
1 x Brake disengage key
1 x Maxi fuse-puller
Fig.1
Fig.2
!
Fig.5
Fig.6