Assembly; Assembling The Product - Aventics SERCOS III Mode D'emploi

Coupleur de bus ddl
Masquer les pouces Voir aussi pour SERCOS III:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 75
50
AVENTICS | SERCOS III | R412012613–BDL–001–AC

Assembly

5
Assembly
Danger of injury if assembled under pressure or voltage!
Assembling when under pressure or voltage can lead to
injuries and damage to the product or system components.
O
Make sure that the relevant system part is not under
voltage or pressure before you assemble the product.
O
Protect the system against being switched on.
5.1

Assembling the product

Danger of injury if assembled incorrectly!
Incorrect assembly can lead to uncontrolled product or system
movements.
O
Make sure that the bus coupler is correctly fastened.
O
Make sure that the device is securely fastened with the
correct tightening torque.
1. Let the bus coupler acclimate itself for several hours before
installation; otherwise water may condense in the housing.
2. Make sure the relevant system part is not under voltage or
pressure.
3. Remove the four mounting screws.
4. Set the bus coupler in the desired position on the mounting
plate (any) or control cabinet (on the side).
5. Tighten the four M5 mounting screws
(tightening torque: 6 Nm).
CAUTION
CAUTION

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

R412012520

Table des Matières