Completely read through the operating instructions, the "Warranty and Additional Information"
!
booklet as well as the latest information under the internet link at the end of these instructions.
Follow the instructions they contain. This document must be kept in a safe place and if the laser
device is passed on, this document must be passed on with it.
Function / Application
The ThermoSpot Plus is an infrared thermometer with an adjustable emission coefficient that can be used
for measuring the temperature of a wide range of surfaces without having to make contact with them.
The instrument measures how much electromagnetic energy is emitted in the infrared wavelength range
and uses this information to calculate the surface temperature.

General safety instructions

– The device must only be used in accordance with its intendedpurpose and within the scope of
the specifications.
– The measuring tools and accessories are not toys. Keep out of reach of children.
– Modifications or changes to the device are not permitted, this will otherwise invalidate the approval
and safety specifications.
– Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
– The device must no longer be used if one or more of its functions fail or the battery charge is weak.
– Please ensure compliance with the safety regulations set out by local and national authorities with
regard to the correct and proper use of the device.
Safety instructions
Using class 2 lasers
– Attention: Do not look into the direct or
reflected beam.
– Do not point the laser beam towards persons.
– If a person's eyes are exposed to class 2 laser
radiation, they should shut their eyes and
immediately move away from the beam.
Safety instructions
Dealing with electromagnetic radiation
– The measuring device complies with electromagnetic compatibility regulations and limit values
in accordance with EMC-Directive 2014/30/EU.
– Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity
of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference
or be subject to hazards or interference.
– The measuring accuracy may be affected when working close to high voltages or high electromagnetic
alternating fields.
ThermoSpot Plus
Laser radiation!
Do not stare into the beam!
Class 2 laser
< 1 mW · 650 nm
EN 60825-1:2014/AC:2017
– Under no circumstances should optical instruments
(magnifying glass, microscope, binoculars)
– Do not use the laser at eye level (1.40...1.90 m).
– Tampering with (making changes to) the laser
device is not permitted.