Installation; Transportation; Lifting And Handling; Positioning - SIFA QUAD Mode D'emploi

Vitrine patissiere/confisere
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2 INSTALLATION

2.1 TRANSPORTATION

Two wooden strips are fixed onto the base structure of the display unit and positioned lengthways.
The display unit is usually shipped using overland transport.
Normal packaging consists of a polyethylene cover; the company provides special packaging on
request.

2.2 LIFTING AND HANDLING

The display unit should be lifted out of the transporting
vehicle using a fork lift truck (fig. 5).
CAUTION!
The lifting platform fork must be at least
1 m / 3.2 ft long.
Position the display unit correctly by
placing its centre of gravity in the middle
of the support area on the lifting vehicle
forks.
Once the equipment is on the ground, we recommend the packaging is removed immediately in order to
check the item is intact and has not been damaged during transportation. The following should be checked
in particular:
- The condition of the finished surfaces.
- The supporting elements for the glass surfaces.
- The opening mechanism of the front glass panel.
- The adherence of the seal cushioning the front glass panel.
NOTE:
The carrier must be notified of any damages immediately. Under no circumstances, however,
may the damaged display unit be returned to the manufacturer without prior notice or written
authorisation.

2.3 POSITIONING

Before installing the equipment, please take the following considerations into account:
- Leave a space of at least 50 cm (1.6 ft) between the unit and any other item, on both the operator side
and the customer side, so that air can circulate in the motor compartment.
- Calculate the space required to operate the unit and perform maintenance in safe conditions.
- Make sure there is a suitable earthing system as specified by current legislation.
- Remove all packaging protecting the display unit.
- If the display unit is located in the centre of the room, an under-floor or overhead channel must be provided
for the power supply cable.
Place the display unit in the chosen position, remembering to remove the two strips at the base of the unit
before the final position is achieved.
The display unit should be positioned in such a way that it is perfectly level.
CAUTION!
This procedure must be performed with great care and safety precautions should be
taken.

2.4 ENVIRONMENTAL SPECIFICATIONS

CAUTION!
The display unit can operate at a maximum room temperature of 35°C and at 60% relative
humidity, as long as the equipment regularly undergoes scheduled maintenance.