Location Requirements - Haier HMV1472BHS Instructions D'installation

Masquer les pouces Voir aussi pour HMV1472BHS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Nylon Grommet (for metal
cabinets)
Glass Tray
PARTS NEEDED
M6-1.00 Self-aligning Machine Screw (2) - of the length needed to go through
the cabinet bottom, filler block (if needed for recessed bottom cabinets), and
into the top of the microwave.

LOCATION REQUIREMENTS

a
16½" (42 cm)
24" (61.0 cm)
d
The space between the cabinets on each side of the range must be at least 24"
(61 cm) wide and free of obstructions.
Grounded electrical outlet inside overhead cabinet. See "Electrical
Requirements" section.
If you are going to vent the microwave oven to the outside, see "Install
Microwave Oven" for exhaust and duct preparation.
When installing the microwave oven beneath smooth, flat cabinets, follow the
instructions on the Top Cabinet template for power cord clearance.
TOP CABINET TEMPLATE
Top Cabinet Template
Turntable Ring
b
30"
(76.2 cm)
min.
c
4
REAR WALL TEMPLATE
Rear Wall Template
Grounded 3 Prong Outlet
A
Bottom edge of cabinet
B
needs to be 30" (76.2 cm)
or more from the cooking
surface.
Backsplash
C
66" (167.6 cm) or more
D
from the floor to the top
of the microwave

Publicité