6.1 Moving onto an obstacle
If the lift lowers onto an obstacle, the system automatically switches off, as soon as an unevenness
of approx. ± 40 mm is detected.
6.1.1 Remove the obstacle
Access to the DIP switch may only be done by a trained, authorised specialist.
•
Open the control cabinet Caution voltage!!!
Figure 5: Circuit board - lean controller
•
Set all DIP switches to the "off" position.
•
Place the DIP switch 1 and 2 to the "on" position.
•
Warning: This process can only be done when the lift is not in the uppermost position.
•
Caution, the vehicle and vehicle response must be monitored continuously.
•
Push the "Raise" button until the obstacle can be removed.
•
Observe any eccentric running Levelness!
•
The lift rail that is lower must be lifted with the help of the dip switch, (see Section "5.4")
Manual equalisation of the lift rails
6.1.2 Measurement system error
To do a reset of the measurement system see sequence Section 6.3 1 Resetting the
measurement system.
Operating Manual and Inspection Book
POWER LIFT HL 2.60 SST DG
Lower LED flashes in a 1
second rhythm in normal
operation
DIP switch
- 21 -