locAtion
The pump should be placed on a flat, level surface. Connect the power cord to the electrical outlet. In order to start, the pump must be immersed in water. If the unit
does not start immediately, tilt the output up slightly to eliminate any air bubbles in the system. Ensure that the pump is always submersed during operation.

Flow control

All models have a flow adjuster to increase or decrease flow rate.
therMAl oVerloAd protection
This pump is configured with automatic thermal overload protection. If the motor overheats, the protection device will cut off the power automatically. If this occurs,
switch off the power at the mains supply to the pump. Then unplug the pump. Check for the cause. Usually it will be debris blocking the inlet of the pump or
obstructing the impeller. Remove the obstruction and wait for 15 minutes. Plug in the pump and the motor will resume operating.
troUbleshooting
low Flow FroM pUMp
- Check that the strainer cage is free from debris.
- Check hose for blockages.
- Check that the fountain heads are free from debris.
- Check that the flow control is not set to the lowest flow.
poor FoUntAin displAy
- Clean fountain head.
- Check that the flow control is not set to the lowest flow.
no Flow FroM pUMp
- Check that the power supply is on – check breaker.
- Check mains plug (UK market only) and wiring.
- Disconnect the pump, remove impeller assembly and clean, and then reconnect the pump.
MAintenAnce
AlwAys UnplUg pUMp beFore perForMing MAintenAnce
FoUntAin Jets
Remove jet head from Riser Pipe. Rinse parts in clean water and reassemble.
iMpeller
cAUtion: The pump motor includes a high quality ceramic shaft that provides long-lasting, reliable performance when properly maintained. However, extreme
care should be taken when handling the shaft during maintenance. Avoid dropping or pressing too hard on it to prevent breakage or hairline fractures, which may
cause the shaft to snap while in operation.
This pump is free from lubricants and requires no special maintenance. However, to keep the pump operating in the best condition, regular maintenance and
cleaning is needed.