Yamaha WaveRunner FX140 Manuel D'entretien page 538

Masquer les pouces Voir aussi pour WaveRunner FX140:
Table des Matières

Publicité

+
ELEC
È
É
ELECTRICAL ANALYSIS
Peak voltage adaptor
NOTE:
• Throughout this chapter the peak voltage
adaptor's part number has been omitted.
Refer to the following part number.
• The peak voltage adaptor should be used
with the digital tester.
Peak voltage adaptor:
YU-39991/90890-03172
• When measuring the peak voltage, connect
the peak voltage adaptor to the digital circuit
tester and switch the selector to the DC volt-
age mode.
NOTE:
• Make sure that the adaptor leads are prop-
erly installed in the digital circuit tester.
• Make sure that the positive pin (the "+" mark
facing up as shown) on the adaptor is
installed into the positive terminal of the
tester.
• The test harness is needed for the following
tests.
È Voltage measurement
É Peak voltage measurement
Test harness
Checking steps:
• Disconnect the coupler connections.
• Connect the test harness between the
couplers.
• Connect the tester terminals to the termi-
nals which are being checked.
• Run the engine and observe the mea-
surement.
NOTE:
If the lighting coil and pulser coil(s) are mea-
sured unloaded, disconnect the test harness
on the output side coupler.
7-13