Installing the Heki2

Supplementary to fig. 4
The scope of delivery includes a mounting set, which is suitable for a roof thickness
of 25 – 32 mm. For roof thicknesses of 33 – 60 mm, you need to have a suitable
mounting set (see table).
➤ Measure your roof thickness W.
➤ Choose a suitable mounting set:
Roof thickness
25 – 32 mm
33 – 39 mm
39 – 46 mm
46 – 53 mm
53 – 60 mm
See fig. 5
➤ Check that the roof light has sufficient space around it (approx. 1 to 2 mm) in the
roof opening.
See fig. 6
➤ Clean the roof opening in the mounting area.
See fig. 7
A
NOTICE!
Observe the instructions of the sealant manufacturer.
➤ Seal the mounting frame with a flexible non-hardening sealing compound (e.g.
SikaLastomer-710).
EN
Mounting bracket
colour
Grey
Black
Yellow
Blue
Red
Screws
∅ 4 x 25 mm
∅ 4 x 32 mm
∅ 4 x 40 mm
∅ 4 x 46 mm
∅ 4 x 52 mm