VIKING MODEL VEV900
EXTERIOR MOUNTED BLOWER
FOR USE WITH VIKING VWH, VIH, VBCV, VICV AND DTWN
24" TO 42" WIDE, 18" HIGH RANGE HOODS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer or your distributor.
2. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnect-
ing means to prevent power from being switched
on accidentally. When the service disconnecting
means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done
by a qualified person(s) in accordance with all
applicable codes and standards, including fire-
rated construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer's guide-
line and safety standards such as those published
by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigera-
tion and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
PLAN THE INSTALLATION
ALL INSTALLATIONS
1. Locate the blower so the length of the duct run and
number of elbows needed are kept to a minimum.
2. Where possible, blower should be centered be-
tween wall studs or roof rafters.
3. Avoid pipes, wires, or other ductwork that may be
running through the wall.
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
WARNING
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the out-
doors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive material and va-
pors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, con-
struction dust, etc. off power unit.
3. Please read specification label on product for
further information and requirements.
4. Electrical circuit, including speed control, (if used),
must be rated 6 AMPS minimum.
Blower Dimensions
28.251 x 24.75 x 7.17
SPECIFICATIONS
MODEL
VOLTS
VEV900
120
1
AMPS
CFM
DUCT SIZE
5.7
900
10 " DIA.

Publicité

Table des Matières
loading

Sommaire des Matières pour Viking Range VEV900

  • Page 1 VIKING MODEL VEV900 EXTERIOR MOUNTED BLOWER FOR USE WITH VIKING VWH, VIH, VBCV, VICV AND DTWN 24" TO 42" WIDE, 18" HIGH RANGE HOODS READ AND SAVE THESE INSTRUCTIONS WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC 5. When cutting or drilling into wall, or ceiling, do not SHOCK, OR INJURY TO PERSONS, OBSERVE damage electrical wiring or other hidden utilities.
  • Page 2 PREPARE THE INSTALLATION PREPARE THE INSTALLATION LOCATION LOCATION ROOF INSTALLATIONS WALL INSTALLATIONS 1. Choose a position on the outside wall. Make sure 1. Locate the blower on the rear slope of the roof. that no wall studs, pipes or wires run through the Place it in a location to minimize duct run.
  • Page 3 INSTALL THE BLOWER INSTALL THE BLOWER ROOF INSTALLATIONS WALL INSTALLATIONS 1. Remove roofing nails from the upper 2/3 of the 1. Place a large bead of caulk on the back side of the shingles around the cutout area and carefully lift the housing along the outer edge.
  • Page 4: Motor Lubrication

    6. Connect ductwork to rough-in plate and tape joint. 10" DAMPER MOUNTS INSIDE DUCTWORK AT LEAST 3" ABOVE CANOPY OUTLET 10" ROUND DUCT HOUSE WIRING WIRE POWER COVER CABLE 7. Turn on power and check blower operation. VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA 99043131E...
  • Page 5: Viking Modèle Vev900 Ventilateur Monté À L'extérieur

    VIKING MODÈLE VEV900 VENTILATEUR MONTÉ À L’EXTÉRIEUR POUR UTILISATION AVEC LES HOTTES DE CUISINE VIKING VWH, VIH, VBCV, VICV ET DTWN, 24" À 42" (76,2 CM À 106,7 CM) DE LARGEUR, 18" (45,7 CM) DE HAUTEUR. VEUILLEZ LIRE CES DIRECTIVES ET LES CONSERVER...
  • Page 6: Préparation De L'emplacement

    PRÉPARATION DE PRÉPARATION DE L’EMPLACEMENT L’EMPLACEMENT POSES SUR LES TOITS POSES SUR LES MURS 1. Choisissez un emplacement pour le ventilateur sur la 1. Choisissez un emplacement sur le mur extérieur. pente arrière du toit. Placez-le de sorte à réduire au Assurez-vous qu’aucun poteau mural, tuyau ou câble ne maximum l’utilisation de conduits.
  • Page 7: Pose Du Ventilateur

    POSE DU VENTILATEUR POSE DU VENTILATEUR POSES SUR LES TOITS POSES SUR LES MURS 1. Appliquez une large bande de produit à calfeutrer à 1. Retirez les deux premiers tiers des clous à toiture des l’arrière du boîtier, le long du rebord extérieur. bardeaux se trouvant autour de la surface de découpe puis soulevez délicatement les bardeaux de manière à...
  • Page 8: Utilisation Et Entretien

    3 po AU-DESSUS DE SORTIE DE VERRIÈRE CONDUIT ROND DE 15,2 CM (10 PO) CÂBLAGE DOMESTIQUE COUVERCLE DU BOÎTIER CÂBLE D’ALIMENTATION DE CÂBLAGE 7. Mettez l’appareil sous tension et vérifiez le fonctionnement du ventilateur. VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA 99043131E...

Table des Matières