MODEL VEV1500
EXTERIOR MOUNTED BLOWER
FOR USE ONLY WITH VIKING VWH/VBCV/VIH/VICV/DTWN - 42"W (ISLAND
ONLY) - 66"W. WALL AND ISLAND HOODS.
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOW-
ING:
1. Use this unit only in the manner intended by the manu-
facturer. If you have questions, contact the manufac-
turer or your distributor.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be
locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
a qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American So-
ciety for Heating, Refrigeration and Air Conditioning
PLAN THE
INSTALLATION
ALL INSTALLATIONS
1. Locate the blower so the
length of the duct run and
number of elbows needed
are kept to a minimum.
2. Where possible, blower
should be centered be-
tween wall studs or roof
rafters.
3. Avoid pipes, wires, or
other ductwork that may
be running through the
wall.
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
MODEL VEV1500
EXTERIOR BLOWER
SOFFIT
WALL HOOD
CANOPY
(island canopy
available)
24" or 27"
TYPICAL ROOF MOUNTED INSTALLATION
WARNING
Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
Blower Dimensions
25 x 30.828 x 12.724
SPECIFICATIONS
MODEL VOLTS
VEV1500
120
10" ROUND
DUCT
ROUGH-IN
WALL HOOD
PLATE
CANOPY
(island canopy
available)
18"
TYPICAL WALL MOUNTED INSTALLATION
1
AMPS
CFM
DUCT SIZE
4.3
1500
10" ROUND ELBOW
10" ROUND DUCT
SOFFIT
18"
24" or 27"
10" DIA.
MODEL
VEV1500
EXTERIOR
BLOWER
ROUGH-IN
PLATE

Publicité

Table des Matières
loading

Sommaire des Matières pour Viking Range VEV1500

  • Page 1 MODEL VEV1500 EXTERIOR MOUNTED BLOWER FOR USE ONLY WITH VIKING VWH/VBCV/VIH/VICV/DTWN - 42”W (ISLAND ONLY) - 66”W. WALL AND ISLAND HOODS. READ AND SAVE THESE INSTRUCTIONS WARNING WARNING Engineers (ASHRAE), and the local code authorities. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOW- 5.
  • Page 2 PREPARE THE INSTALLATION PREPARE THE INSTALLATION LOCATION LOCATION WALL INSTALLATIONS ROOF INSTALLATIONS 1. Locate the blower on the rear slope of the roof. Place it 1. Choose a position on the outside wall. Make sure that no wall studs, pipes or wires run through the opening area. in a location to minimize duct run.
  • Page 3 INSTALL THE BLOWER INSTALL THE BLOWER ROOF INSTALLATIONS WALL INSTALLATIONS 1. Remove the cover and screws. 1. Place a large bead of caulk on the back side of the housing all along the outer edges. 2. Attach an appropriate U.L. approved cable connector in the hole at the rear of the wiring box.
  • Page 4 5. Attach rough-in plate to the studs at the inside top of hood with (4) #10-24 nuts provided. 6. Connect ductwork to rough-in plate and tape joint. 7. Turn on power and check blower operation. VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA 99043941B...
  • Page 5: Modèle Vev1500 Ventilateur Monté À L'extérieur

    MODÈLE VEV1500 VENTILATEUR MONTÉ À L’EXTÉRIEUR À UTILISER UNIQUEMENT AVEC VIKING VWH/VBCV/VIH/VICV/DTWN - 106,7 CM (42”) (ÎLOT UNIQUEMENT) DE LARGEUR - 167,6 CM (66”) DE LARGEUR HOTTES MURALES ET ÎLOTS. VEUILLEZ LIRE CES DIRECTIVES ET LES CONSERVER AVERTISSEMENT AVERTISSEMENT OBSERVEZ LES DIRECTIVES CI-DESSOUS DE MANIÈRE l’air libre.
  • Page 6: Préparation De L'installation

    PRÉPARATION DE L’INSTALLATION PRÉPARATION DE L’INSTALLATION INSTALLATIONS SUR LE TOIT INSTALLATIONS SUR LE MUR 1. Positionez le ventilateur sur la pente arrière du toit. 1. Choisissez l’emplacement sur un mur extérior. Assurez- Placez-le de manière à minimiser la longueur des vous qu’aucun montant, tuyau ou fil ne court dans conduits.
  • Page 7: Installation Du Ventilateur

    INSTALLATION DU VENTILATEUR INSTALLATION DU VENTILATEUR INSTALLATIONS SUR LE MUR INSTALLATIONS SUR LE TOIT 1. Enlevez le couvercle et les vis. 1. Appliquez une grosse bande de mastic à l’arrière du boîtier le long des arêtes extétieures. 2. Fixez un connecteur de câble adéquat portant l’homologation U.L.
  • Page 8: Pose De La Plaque De Raccor- Dement

    à l’aide de (4) écrous n 10-24, inclus. 6. Branchez le conduit à la plaque de raccordement et guipez le joint. 7. Mettez l’appareil sous tension et vérifiez le fonctionne- ment du ventilateur. VIKING RANGE CORPORATION GREENWOOD, MISSISSIPPI 38930 USA 99043941B...

Table des Matières