Specifications

MODEL
POWER
(WATTS)
THX2400UK
2400 @ 240 v
THX3600UK
3600 @ 240 v
THX2400EU
2400 @ 230 v
THX3600EU
3600 @ 230 v
MODEL
HEATER TYPE
OUTPUT
POWER
CONNECTION
APPROVALS
MOUNTING HEIGHT
MOUNTING OPTIONS
PROTECTION RATING
COUNTRY OF MANUFACTURE
THX3600
CURRENT
DIMENSIONS
(AMPS)
(mm)
10
854 x 170 x 80
15
1184 x 170 x 80
10
854 x 170 x 80
15
1184 x 170 x 80
High intensity electric radiant overhead heater with Incoloy 840 element
Refer to model code chart above
230-240 Volts Nominal at 50—60 Hertz, Single Phase
3 Core Cable 2.5mm
AUSTRALIA/CE
MINIMUM
RECOMMENDED
MAXIMUM
Suitable for ceiling, wall, beam mounting. Also available for extension
mount using rigid fixing poles and chain mount bracket.
IPX5 Protection from water ingress from all directions
Australia
WEIGHT
LEAD
(Kg)
LENGTH
(mm)
5
1000
6
1000
5
1000
6
1000
2
2.1 m
2.4 m to 3.5 m
3.5 m (For higher ceiling heights, units can be
lowered using optional bracket kits or refer to the
Heatstrip Max range)
THX2400
PLUG
YES
NO
YES
NO
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Max thx3600ukMax thx2400euMax thx3600eu

Table des Matières