Cord Sets and Receptacles
Use only high quality, well-insulated, grounded
extension cords with the generator's receptacles.
Inspect extension cords before each use.
Check the ratings of all extension cords before you
use them. Check operator's manuals of devices to be
powered for the manufacturer's recommendations.
WARNING Damaged or overloaded electrical
cords could overheat, arc, and burn
resulting in death or serious injury.
• ONLY use cords rated for your loads.
• Follow all safeties on electrical cords.
• Inspect cord sets before each use.
120 Volt AC, 30 Amp RV Outlet (3500 Watt only)
Use a NEMA TT–30 plug with this receptacle. Connect
a 3–wire travel trailer cord set rated for 125 Volt AC
loads at 30 Amps to the plug.
NEMA
TT-30
Hot
120V
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase travel trailer loads requiring up to 3,500
watts (3.5 kW) of power at 29.1 Amps. The outlet is
protected by a push-to-reset circuit breaker.
NOTICE Receptacles may be marked with rating
value greater than generator output capacity.
• NEVER attempt to power a device requiring more
amperage than generator or receptacle can supply.
• DO NOT overload the generator. See Generator Capacity.
12
120 Volt AC, 20 Amp, Duplex Receptacles
The duplex receptacles are protected against overload
by a push to reset circuit breaker.
Use receptacle to operate 120 Volt AC, single–phase,
Ground
60 Hz electrical loads requiring up to 2,400 watts
(Green)
(2.4KW) at 20 Amps of current. Use cord sets that are
rated for 125 Volt AC loads at 20 Amps (or greater).
Neutral
www.powerboss-equipment.com