3
SHUTTER GATE TRAVEL PROGRAMMING
The duration of the opening and closing operations is
adjusted using T.M.
4
OPERATION MODE SELECTION
DISABLE
ENABLE
5
STARTING UP
Final checks
Following installation and programming, start up the
shutter gate and check all the devices installed:
• key commands (transmitter, push button and wall
key)
• safety devices (photocells or mechanical strips)
If the system does not work correctly, find out
why and put it right (see section "Failure
diagnosis" on page 34).
Open / close mode (DIP1=OFF, DIP2=OFF)
Opening is carried out by briefly pressing A.T. (or the first fixed code transmitter
channel).
Closing is carried out by briefly pressing C.T. (or the second fixed code
transmitter channel).
Step-by-step mode (DIP1=OFF, DIP2=ON) and automatic mode (JP1)
Opening is carried out by briefly pressing A.T. (or the first fixed code transmitter
channel).
• Step-by-step closing (JP1=DISABLE): carried out by briefly pressing A.T.
• Automatic closing (JP1=ENABLE): carried out automatically when standby
time finishes, which can be set using the T.E. power meter
The second fixed code transmitter channel activates the RLX relay.
Dead man mode (DIP1=ON, DIP2=OFF)
Opening is carried out by continuously pressing A.T.
Closing is carried out by continuously pressing C.T.
The transmitter is not operational.
Dead man mode in closing (DIP1=ON, DIP2=ON)
Opening is carried out by briefly pressing A.T.
Closing is carried out by continuously pressing C.T.
The transmitter is not operational.
PROGRAMMING AND STARTUP
It is also necessary to correctly set the FCC and FCA limit
switches.
User instruction
1 Instruct the user with regards to the use and
maintenance of the installation and provide him/her
with the user guide.
2 Signpost the shutter gate, showing that it opens
automatically and indicating how to operate it
manually.
Where
appropriate,
operation is using the radio transmitter.
indicate
that
33
CLEVER02 Control panel