1. General information / 2. Safety
Information
... points out useful tips, recommendations and information for efficient and
trouble-free operation.
DANGER!
...identifies hazards caused by electric power. Should the safety instructions not
be observed, there is a risk of serious or fatal injury.
WARNING!
... indicates a potentially dangerous situation that can result in burns, caused by
hot surfaces or liquids, if not avoided.

2. Safety

WARNING!
Before installation, commissioning and operation, ensure that the appropriate
switch has been selected in terms of switching temperature, design and specific
measuring conditions.
Non-observance can result in serious injury and/or damage to the equipment.
Further important safety instructions can be found in the individual chapters of
these operating instructions.

2.1 Intended use

The model TFS35 bimetal temperature switches are used to limit temperatures within a
wide variety of applications.
They monitor the temperature of machinery and equipment and, for example, switch off
machinery if it overheats or switch on a fan to cool the equipment.
Bimetals form the basis of the model TFS35 temperature switches. Temperature sensing is
carried out by a bimetallic disc, which snaps over when the Nominal Switching Temperature
(NST) is reached. On cooling back down to the Reset Switching Temperature (RST), the
switch returns to its original state, so that the monitored equipment can again work normally.