TROUBLESHOOTING
PROBLEM
The burner will not
light with a match.
No gas flow or an
obstructed gas
flow.
POSSIBLE CAUSE
1. Match not reaching burners
(when holding match with
hand).
2. Empty tank.
3. Poor connection between
valve regulator and LP
cylinder coupling.
4. Burner inlet blocked.
1. Tank valve not on or fully
opened.
2. Empty tank.
3. Poor connection between
valve regulator and LP
cylinder coupling.
4. Burner inlet blocked.
CORRECTIVE ACTION
1. Use match holder found in
cabinet door.
2. Check fuel level and refill tank if
necessary.
3. Turn off grill knobs, close the LP cylinder
valve at top of cylinder and check the
connection between the regulator valve
and cylinder coupling. Disconnect and
reconnect, if necessary.
4. Clean the burner inlet (venturi) and
burner as described by the Care and
Maintenance section in the manual.
1. Fully open tank valve by turning
counterclockwise.
2. Check fuel level and replace fuel if
necessary.
3. Turn off grill knobs, close the LP cylinder
valve at top of cylinder and check the
connection between the regulator valve
and cylinder coupling. Disconnect and
reconnect, if necessary.
4. Clean the burner inlet (venturi) and
burner as described by the Care and
Maintenance section in the manual.
27