Profroid QUIETOR CITY GQH G Notice D'instructions page 59

Table des Matières

Publicité

Medium temperature
Moyenne température
R134A
Designation
QUIETOR GQH ZBD42G T3 TW R134A
QUIETOR GQH ZBD58G T3 TW R134A
QUIETOR GQH ZBD57G T3 R134A
QUIETOR GQH ZBD76G T3 R134A
QUIETOR GQH ZBD76G T3 TW R134A
QUIETOR GQH ZBD90G T3 TW R134A
QUIETOR GQH ZBD114G T4TW R134A
QUIETOR GQH ZBD152G T4TW R134A
R134A
Designation
QUIETOR GQH ZBD57G T3 R134A
QUIETOR GQH ZBD76G T3 R134A
QUIETOR GQH ZBD42G T3 TW R134A
QUIETOR GQH ZBD58G T3 TW R134A
QUIETOR GQH ZBD76G T3 TW R134A
QUIETOR GQH ZBD90G T3 TW R134A
QUIETOR GQH ZBD114G T4TW R134A
QUIETOR GQH ZBD152G T4TW R134A
Q
SEPR
Seasonal
Annual
energy
electric.
Rated
perfom.
CALCUL
consum.
ratio
ecodesign
(kWh/a)
SEPR
13 104
3.04
SEPR
16 892
2.92
SEPR
16 447
3.01
SEPR
21 917
2.94
SEPR
21 210
3.04
SEPR
26 563
2.81
SEPR
30 365
3.16
42 489
2.9
SEPR
LEGENDE : P
- Cooling capacity
A
LEGENDE : P
- Puissance frigorifique
A
Evap. Temp. t = -10°C / Amb. Temp. Ta = + 15°C
Declared
D
C
CALCUL
P
compressor
C
ecodesign
(kW)
(kW)
SEPR
9.58
2.25
SEPR
12.51
3.26
SEPR
7.66
1.61
SEPR
9.49
2.31
SEPR
12.35
3.1
SEPR
14.48
4.06
SEPR
18.63
4.93
SEPR
24.08
7.18
Evap. Temp. t = -10°C / Amb. Temp. Ta = + 32°C
D
D
A
A
P
Rated
A
compressor
fan
(kW)
(kW)
(kW)
(kW)
6.48
2.55
0.83
3.38
8.01
3.50
0.83
4.33
8.06
3.48
0.83
4.31
10.48
4.70
0.83
5.53
10.49
4.59
0.83
5.42
12.16
5.34
0.83
6.17
15.62
7.37
0.80
8.17
20.05
10.04
0.80
10.84
DA - Power input
DA - Puissance absorbée
Declared
Declared
D
C
D
COP
fan
C
C
(kW)
(kW)
0.83
3.08
3.11
0.83
4.09
3.06
0.83
2.44
3.14
0.83
3.14
3.02
0.83
3.93
3.14
0.83
4.89
2.96
0.80
5.73
3.25
0.80
7.98
3.02
47
R134A
Evap. Temp. t = -10°C / Amb. Temp. Ta = + 25°C
Rated
Declared
D
B
D
A
COP
P
compressor
A
B
(kW)
(kW)
1.92
6.97
2.16
1.85
8.62
3.01
1.87
8.69
2.97
1.90
11.31
4.11
1.94
11.21
3.97
1.97
13.11
4.87
1.91
16.86
6.36
1.85
21.71
8.87
R134A
Evap. Temp. t = -10°C / Amb. Temp. Ta = + 5°C
Declared
D
D
D
D
P
compressor
fan
D
(kW)
(kW)
(kW)
10.47
1.53
0.83
13.7
2.41
0.83
8.35
1.05
0.83
10.35
1.61
0.83
13.49
2.22
0.83
15.84
3.25
0.83
20.4
3.49
0.8
26.45
5.5
0.8
LEGENDE : P
- Cooling capacity
A
LEGENDE : P
- Puissance frigorifique
A
Declared
Declared
D
B
D
COP
fan
B
B
(kW)
(kW)
0.83
2.99
2.33
0.83
3.84
2.24
0.83
3.80
2.29
0.83
4.94
2.29
0.83
4.80
2.34
0.83
5.70
2.30
0.80
7.16
2.35
0.80
9.67
2.25
Cdc
Declared
Declared
Degrad.
D
COP
Coeff.
D
D
(kW)
Cdc
2.36
4.44
0.25
3.24
4.23
0.25
1.88
4.44
0.25
2.44
4.24
0.25
3.05
4.42
0.25
4.08
3.88
0.25
4.29
4.76
0.25
6.3
4.20
0.25
DA - Powerinput
DA - Puissanceabsorbé

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Quietor city gql g

Table des Matières