ENGLISH
Page 8
CAUTION
Make sure to perform the following step BEFORE
mounting the enclosure onto the mounting bracket,
otherwise, damage to the threaded hole of the
mounting bracket may occur.
7.
Open the front cover of the controller and locate
the fastening hole under the ground bar. Drill a
3/16" hole through the plastic enclosure.
8.
Line up the slot in the controller enclosure with
the guide in the mounting bracket and hook on to
mount.
9.
Secure the controller enclosure to the mounting
bracket with the single fine thread Phillips screw
provided.
Controller
Screw
Drill a 3/16" hole before
mounting onto the bracket
Figure 1.
Mounting the Controller Enclosure
3.2
Mount the User Interface for Remote
Access
The user interface (UI) may be installed in a more
convenient location away from the equipment pad.
To set up the UI remotely, you will need to purchase
a standard telephone cable the length of the remote
distance to connect the UI to the controller unit.
NOTE: The UI MUST be mounted OUTDOORS where
a pool service technician may conveniently access it.
AquaLink
Z4 Controller | Installation Manual
®
Screws (4)
Anchors (4)
Mounting
Bracket
WARNING
The controller is not to be considered as suitable for
use as service equipment. Therefore it is required to
have the appropriate means of disconnection, circuit
isolation, and/or branch circuit protection installed
upstream of the power/control center.
1.
Using the holes in the metal bracket as a guide,
drill two (2) holes on the surface where the UI will
be mounted.
2.
Screw the bracket to the surface using two (2)
screws.
3.
Remove the UI from the front of the controller
enclosure and attach magnetically to the mounting
plate.
4.
Use the blank plastic face plate provided to cover
the UI housing when UI is removed. Attach
face plate to enclosure door with the two screws
originally used to fasten the UI to the door.
Section 4.
High Voltage Wiring
WARNING
Potentially high voltages in the AquaLink Z4
controller can create dangerous electrical hazards,
possibly causing death, serious injury or property
damage. Turn off power at the main circuit feeding
the AquaLink Z4 controller to disconnect the power
center from the system.
WARNING
Zodiac Pool Systems, Inc. recommends that any
procedure requiring potential contact with live
electrical wiring and/or parts other than cords and
plugs connected to electrical outlets, be completed
by a contractor who is licensed and qualified in
pool equipment as described on the front cover of
this manual. Failure to follow warning notices and
instructions may result in property damage, serious
injury, or death.
All high voltage wiring must be done by a licensed
electrical contractor.
NOTE: See Figure 2. AquaLink Z4 Electrical Wiring
Diagram for specific wire locations and
connections.