Starting The Battery Conditioner - Dometic GROUP Waeco PerfectBattery BC100 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
PerfectBattery BC100, BC200
6

Starting the battery conditioner

NOTICE!
A
Set up the device in a location where it is protected against
moisture and moist air.
Ensure that
 The installation location is well ventilated and
 The mounting surface is flat and sufficiently firm.
NOTE
I
On some vehicles, the 12/6 V socket only works when the ignition
is switched on.
In this case, connect the battery conditioner direct to the battery.
➤ Check that the battery is in good condition.
➤ Check the following:
– The battery housing for damage
– The fluid level in the battery
If necessary refill the battery with distilled water.
– The pole contacts
Clean off any dirt present.
– Check the battery voltage with a voltmeter: It should not be below 9 V
(MBCC-100) or 4.5 V (MBCC-200).
If the voltage is less than 9 V (12 V batteries) or 4.5 V (6 V batteries)
a cell may be defective. In such a case, the battery is defective and
may not be recharged.
➤ Switch the vehicle ignition off.
➤ Plug the charging plug (fig. 2 1, page 3) of the battery conditioner into
the 12/6 Vg socket (e.g the cigarette lighter) or
➤ ... connect the adapter cable (fig. 2 2, page 3) to the battery terminals
on the battery (fig. 2 3, page 3):
– Positive terminal of the battery: red cable
– Negative terminal of the battery: black cable
NOTE
I
If the red "Incorrect Polarity" LED (fig. 1 5, page 3) glows when
connecting to the 12/6-Vg socket, you need to connect the device
directly to the battery using the adapter cable (fig. 2 2, page 3).
➤ Plug the power cable of the battery conditioner into a 230-V/50-Hz socket.
EN
Starting the battery conditioner
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Waeco perfectbattery bc200

Table des Matières