3. INSTALLATION
3.1. BEFORE USING THE APPLIANCE
• Remove all the external and internal packaging. Clean the internal surfaces with a soft cloth and
warm water. The unit may contain residual smells at first, these will disappear as the unit begins
to cool.
• Before connecting the appliance to the mains, leave it to rest in vertical position for at least 24
hours. This will reduce the possibility of malfunctioning in the cooling system caused by
transportation. During this time, it is recommended to leave the door open to dispel any residual
smells.
• The door can be opened either from the left or from the right. The unit is delivered with the door
opening on the left-hand side. If you wish to open the door on the right, follow the instructions in
"changing the door hinges".
• Change the door handle round if necessary.
3.2. INSTALLATION
PLANS AND DIMENSIONS FOR INSTALLATION: SEE PAGES AT THE END OF THIS MANUAL.
• This appliance is designed to be installed either fitted or free-standing.
• WARNING: Do not store or install the unit in the open. This unit is designed for indoor use only.
• WARNING: Do not install the unit in a washroom area. Avoid placing the unit in damp locations.
• Place the unit on a floor with sufficient strength to bear the weight of the unit when full. To level
the unit, adjust the front levelling foot at the bottom of the unit.
• When installing free-standing, it is necessary to leave 100 mm of space between the rear and
sides of the unit to allow for air circulation to cool the compressor and condenser, which will save
energy. When installed built-in, it is also necessary to leave 5 mm on each side and at the top, to
guarantee adequate ventilation. Make sure that the air outlet at the front of the unit is not covered
or obstructed.
• Place the unit out of direct sunlight and sources of heat (stove, heater, radiator, etc.) Direct
sunlight can affect the acrylic coating and the heat of the sun can increase energy consumption.
Extremely cold ambient temperatures could also cause the unit to malfunction.
• Connect the unit to an exclusive and easily accessible mains socket. Any query about power
and/or ground connection should be directed to a qualified electrician or an authorised service
centre.
This device must be installed with all its electrical, plumbing and drainage connections in
•
compliance with national and local regulations.
IMPORTANT: HIGH HUMIDITY ENVIRONMENTS
At times of high humidity, there may be some condensation on the external surfaces of the glass door. This
condensation will disappear when the levels of humidity decrease. To prevent this from happening, it is
recommended to install the unit in a location with sufficient ventilation, in a place with dry air or air
conditioning.
NOTE: The mains plug of the unit should be accessible.
11