The Fuel System:.The.hose/regulator.assembly.attaches.to.the.propane.gas.supply..The.
propane.gas.moves.through.the.automatic.control.valve.and.out.the.injector.
The Air System:.The.motor.turns.the.fan..The.fan.pulls.air.into.and.around.the.combustion.
chamber..This.air.is.heated.and.provides.a.stream.of.clean,.hot.air.
The Ignition System:.The.direct.spark.ignitor.(DSI).sends.voltage.to.the.spark.ignitor...The.
spark.ignitor.ignites.the.fuel.and.air.mixture.
The Safety Control System:.There.are.4.independent.systems:
1.. Flame Sensor: This system causes the heater to shut down if the flame goes out.
2.. Thermal Switch:.This.system.causes.the.heater.to.shut.down.if.the.heater.gets.too.hot.
(blocked.openings).
3.. Air Pressure Switch:.The.system.will.not.allow.the.heater.to.start.if.there.is.not.adequate.
air flow.
4.. ODS - Oxygen Depletion System:.This.system.shuts.down.the.heater.if.the.oxygen.level.
drops below the specified level (18%).
ODS Operation: Burner porting "blows" out causing flame sensor to cool, shutting down heater.
Cool.
Air.In.
(Back)
DSI
Power.Cord
Thermal.Switch
Hose/Regulator.

Assembly

Ignitor,.Flame.
Sensor.and.ODS
1.. Remove. all. packing. items. applied. to.
heater for shipment. Keep plastic cover
caps. (attached. to. inlet. connector. and.
hose/regulator.assembly).for.storage.
120193-01A
THeory oF oPeraTion
Fuel
Figure 2 - Cross Section Operational View

UnPacking

www.desatech.com
Air.for.Fuel.
System
2.. Remove.all.items.from.carton.
3.. Check. all. items. for. shipping. damage.. If.
heater.is.damaged,.promptly.inform.dealer.
where.you.bought.heater.
Motor.and.
Blower
Assembly
Air.Pressure.Switch
Clean.
Heated.
Air.Out.
(Front)
Combustion.Chamber
Burner
Injector
7