Optional Light Kit Installation
Remove three screws from side of switch hub (as shown in figure below).
Remove hub cover from hub and pop out center plug. Carefully thread
wires from light kit through the center hole in hub cover. At this point
attach light kit into hub cover by screwing center all-thread from light kit
into the center hub cover. Lock the all-thread in place on the inside of the
hub using the 3/8" nut provided. Attach white wire from light kit to white
wire in hub, using wire nuts. Next, attach black wire from light kit to blue
wire in switch hub. Carefully push wires up into hub and replace hub cover
using screws removed earlier.
Screws
Center Screw
14
Operation Instructions
1. The sequence of operation for the motor pull/chain switch is OFF-HI-
MED-LOW.
2. Push the slide switch RIGHT for FORWARD, and LEFT for REVERSE
action of the blades.
3. The pull chain switch for the lighting is two positions - ON/OFF.
4. The pull chain switch for the uplighting is on/off.
takes 4-60W Candelabra bulbs (not included).
Slide Switch
Light Pull Chain
CAUTION
Even if your fan is mounted with the blades more than 7 feet from the floor, be
careful to avoid placing your raised arms or any object in the path of the blades.
Switch Hub
Center Plug
NOTE: Sentry Uplighting
Motor Pull Chain

Electrical Connections

Connect black and blue (if provided) fan wires to black outlet wire. Connect
white fan wire to white outlet wire and green grounding lead wire from the
grounding conductor to the supply circuit (see figure A). Use wire connectors
provided with your fan. No loose strands or loose connections should be
present. After wires have been connected, they must be spread apart so the
green and white are on one side of the outlet box and the black and blue
are on the other side. Turn
splices upward and carefully
push all wiring into outlet
box. For optional wall
Black
control see figure B or
Figure C for alternate wiring.
When wall switches are employed,
switches should be UL listed
for use with ceiling fan.
NOTE: Make sure fan on/off switch
is always at "high speed" location if
your fan is controlled by additional
wall switch.
White
Black
Light Switch
Figure B
Ground
White
Blue
Black
Figure A
Optional Light
Ground
Black
Blue
Green
White
Optional Light
Green
White