CRX
13
Technical data
ACDC models:
DC models:
Refrigerator compartment capacity:
Freezer compartment capacity:
Capacity:
Voltage:
Power consumption (AC)
(ACDC models only):
Rated current
12 Vg:
24 Vg:
100 Vw (ACDC models only):
240 Vw (ACDC models only):
Cooling temperature range
Refrigerator:
Freezer:
Fast cooling (without dividing wall):
Climatic class:
Relative humidity:
Short-term inclination:
Max. pressure:
Propellant:
Refrigerant:
Refrigerant quantity:
CO
equivalent:
2
Global warming potential (GWP):
EN
CRX50
CRX65
CRX1050
CRX1065
CRX0050
CRX0065
41.2 l
4.4 l
45 l
12 Vg or 24 Vg
100 – 240 Vw (ACDC models only)
40 W
45 W
5.0 A
5.5 A
2.6 A
2.8 A
1.14 A
1.22 A
0.53 A
0.58 A
+3 °C to +12 °C
–15 °C to –5 °C
maximum –6 °C ± 2 °C
Max. 90 %
maximum 30°
LP 11 bar/HP 25 bar
C
R134a
38 g
42 g
0.054 t
0.060 t
1430
Technical data
CRX80
CRX1080
CRX0080
50 l
70.6 l
7.0 l
7.5 l
57 l
78 l
48 W
5.6 A
2.9 A
1.23 A
0.56 A
T
H
5
10
48 g
0.069 t
35