Safety guidelines
ATTENTION!
• The LED is a class 2 source (Po < 1mW) in compliance with international standard IEC 60825-1. NEVER CONTINUOUSLY STARE INTO THE
LASER SOURCE.
The light emitted may cause eye damage in the event of direct radiation without eye protection.
Always use the light with the protective screen (provided) or eyewear that protects against radiation emitted by the blue light up to a wave length
of 520 mm.
Do not aim the light beam in anyone's eyes.
• The light emitted may damage soft tissues (oral cavity mucous, gums, skin).
Be extremely careful to direct the light precisely on the material to be cured.
• Do not use the device on patients taking photosensitising drugs.
• People with eye diseases, such as those who have had cataracts removed or retina diseases must be adequately protected When the
curing lamp is used, for example with s uitable protective eyewear.
• Do not pull the power cord.
• Do not expose the handpiece to excessive vibrations.
• Do not drop the handpiece and in particular the fi ber optic. The lamp may break if accidentally banged.
Check the condition of the handpiece if it has been banged or dropped before using the curing light. Try to turn on the light and check operation
fi rst without using it on the patient.
If cracked, broken or if there are any other faults, do not use the curing light on the patient and contact the technical service depart-
ment.
The fi ber optic is rather delicate and may crack or break if banged, affecting the fi nal amount of light emitted. If dropped, carefully inspect the fi ber
optic to verify if it is cracked or broken. If cracked, a strong light appears in the spot in which the fi ber is cracked. In all these cases, the fi ber optic
must be replaced.
• The curing light handpiece (sold separately) can be connected only to dental units with connections for this curing lamp. Connection to
any other equipment may damage the circuits inside the lamp and seriously injure the user and patient.
• The curing lamp handpiece is not protected against liquid penetration (IP20).
While cleaning and disinfecting, be careful not to let the detergent get inside the device.
• The curing lamp handpiece is not suitable for use in the presence of a mix of infl ammable anaesthetic gas with oxygen or nitrous oxi-
de.
• The equipment is designed for intermittent operation: (60 sec work – 13 min. pause).
Cleaning
The curing lamp may be a vehicle for cross contamination between patients.
The most contaminated parts are the fi ber optic and eye protection.
Only the fi ber optic is autoclavable with water steam at 135 °C. Always clean the fi ber optic before sterilizing.
ATTENTION!
• The fi ber optic is able to support 500 autoclave cycles after which it tends to become dull and may therefore emit less light. Contact the ma-
nufacturer to purchase original spare parts
• Periodically check the autoclave as directed by the manufacturer; temperatures that exceed the indicated limit may damage the fi ber optic.
The handpiece and eye protection cannot be put in autoclave; disinfect them with suitable products and cover the handpiece with disposable plastic
wrap.
Use soft disposable paper towels to disinfect the handpiece and eye protection. Do not use harsh products or soak in liquids.
ATTENTION!
• The curing light handpiece is NOT suitable for autoclave.
• The curing light handpiece is not protected against penetration of liquids therefore it CANNOT be soaked in solution to be sterilized.
• The outside of the lamp should be disinfected with the fi ber optic on. Do not use any type of disinfectant on the exposed optical surface
of the handpiece When the fi ber is removed. The surface will become irreparably opaque if it comes into contact with disinfectant.
Maintenance
This equipment does not require any particular type of maintenance. Only technicians authorized by the manufacturer can replace and/or repair the
handpiece and dental unit. The handpiece has been purposely constructed in a manner that requires specifi c tools to open it and therefore it cannot
be removed by the user. The warranty is automatically void if the handpiece is altered in any way.
Troubleshooting
• Limited curing capacity
Check the condition of the fi ber optic and make sure it is clean
If the problem persists, call Technical Service
• Light shuts off before the end of the cycle (LED indicator fl ashes)
The overload cutout has tripped; let the light cool down.
Disposal at end of service life
• Never throw out the equipment in regular trash.
• Observe current local regulations regarding disposal of the equipment at the end of its service life.
• Due to the possibility of cross contamination, disinfect the equipment before disposing.