CFX35, CFX50
In "HIGH" mode, the battery monitor responds faster than at the levels "LOW"
and "MED" (see the following table).
Battery monitor mode
Switch-off voltage at 12 V
Restartvoltage at 12 V
Switch-off voltage at 24 V
Restart voltage at 24 V
The battery monitor mode can be selected as follows:
➤ Switch on the cooler.
➤ Press the "SET" button (fig. 3 4, page 3) three times.
➤ Use the "UP +" (fig. 3 7, page 3) or "DOWN –" (fig. 3 6, page 3)
buttons to select the battery monitor mode.
✓ Digital display will be as follows:
Lo (LOW), Πd (MED), Hi (HIGH)
✓ The selected mode then appears in the display for a few seconds. The
display flashes several times before it returns to the current temperature.
I
NOTE
When the cooler is supplied by the starter battery, select the
battery monitor mode "HIGH". If the cooler is connected to a
supply battery, the battery monitor mode "LOW" will suffice.
EN
LOW
MED
10.1 V
11.4 V
11.1 V
12.2 V
21.5 V
24.1 V
23.0 V
25.3 V
Operation
HIGH
11.8 V
12.6 V
24.6 V
26.2 V
17