Lubrication - Binks TROPHY Serie Manuel De Service

Masquer les pouces Voir aussi pour TROPHY Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
BINKS "TROPHY" SERIES AUTOMATIC SPRAY GUN
Air Cap
Spray Pattern
Air Cap
Part No.
16
46-6505
CONNECTING GUN TO MATERIAL HOSE
Gun should be connected by a suitable length of 3/8"
diameter material hose fitted with a connector with a
3/8" NPS(f) nut at gun end. 1/4" diameter hose is
recommended for use with low viscosity materials. (Fluid
hoses of different composition are available for special
fluids. See Binks hose catalog for hose selection.)
CONNECTING GUN TO ATOMIZING AIR
Gun should be connected by a suitable length of 5/16"
OPERATING THE BINKS "TROPHY" SERIES AUTOMATIC SPRAY GUN
CONTROLLING THE MATERIAL FLOW
When fed from a pressure supply, an increase in the
material pressure will increase the rate of flow. Correct
fluid nozzle size insures correct material flow rate. If
necessary, fluid flow can also be adjusted by adjusting
the amount of needle travel. This is done by adjusting
control knob (24) until the correct needle travel is
achieved.

LUBRICATION

Monthly: Remove piston assembly (17) and lubricate the
air cylinder chamber and needle valve spring with a
coating of Gunners Mate (35). Also, lubricate side port
control assembly (9) with oil.
CAUTION
!
Never use lubricants containing silicone since
these lubricants can cause finish defects.
Binks Gunners Mate (35) is recommended.
www.carlisleft.com
AIR CAP AND FLUID NOZZLE SELECTION CHARTS
CHART 13: ROUND SPRAY
AIR CAP AND FLUID NOZZLE SELECTION CHART
CFM
@
Range
30 PSI
50 PSI
2 – 4"
5.6
SETUP FOR SPRAYING
CFM
CFM
@
@
Fluid Nozzle
70 PSI
45-11050 series,
7.8
10.5
1.0 mm – 1.8 mm
or 3/8" diameter air hose fitted with a connector and a
1/4" NPS(f) nut at gun end.
CONNECTING GUN TO CYLINDER AIR
Gun should be connected with 3/16" I.D. or 1/8" I.D. air
hose of shortest length possible with 1/4" NPS(f)
connector. Cylinder air must be connected to a 3-way
manual air valve or 3-way solenoid valve to operate
properly.
ADJUSTING THE SPRAY PATTERN
The width of the spray pattern is controlled by the side
port control assembly (9). (See page 4). Turning this
control clockwise until it is closed will give a round spray,
turning it counterclockwise will widen the spray into a
fan shape. The fan spray can be turned anywhere
through 360° by positioning the air cap (5) relative to
the gun. To effect this, loosen air cap assembly, position
nozzle, then, re-tighten air cap assembly.
MAINTENANCE
REMOVAL OF PISTON
To remove the piston, first unscrew the end cap (15),
remove two springs (16 & 23) and pull out the material
needle (22). Remove the piston by screwing needle
adjusting knob (24) into piston (21). See page 13 for
details.
TO REPLACE NEEDLE SEAL AND GLAND
ADAPTER IN FLUID INLET
See instructions on page 13.
12 / 20
Typical Coatings
Lacquers, Enamels
77-3049-R2.7 (8/2017)