• Consult with the customer concerning the location of installation.
• Do not install the water heater where the exhaust will blow on outer walls or material not resistant
to heat. Also consider the surrounding trees and animals.
The heat and moisture from the water heater may cause discoloration of walls and resinous
materials, or corrosion of aluminum materials.
• Install in a location where the exhaust gas flow will not be affected by fans or range hoods.
• Take care that noise and exhaust gas will not affect neighbors.
Avoid installation on common walls as the unit will make some
operational noises while it is running.
• Before installing, make sure that the vent termination (or the vent
cap in an outdoor installation) will have the proper clearances
according to the National Fuel Gas Code (ANSI Z223.1).
[For outdoor installation only]
• Install the water heater in a location where it is free from obstacles and stagnant air.
• Do not install the water heater near staircases or emergency exits.
• Do not locate the vent termination directed towards a window or any
other structure which has glass or wired glass facing the termination.
• Avoid installation where the unit will be exposed to excessive winds.
[For indoor installation only]
• Avoid installation above gas ranges or stoves.
• Avoid installation between the kitchen fan and stove.
If oily fumes or a large amount of steam are present in the
installation location, take measures to prevent the fumes and
steam from entering in the equipment.
[For NR111-SV only]
• Make sure that the location allows installation of the exhaust
vent as specified.
• For outdoor installation, use the outdoor vent cap.
If it is necessary to vent above the roof line in an outdoor
installation, use high temperature sealant around the flue collar
for rain protection.
State of California: The water heater must be braced, anchored or strapped to avoid moving during an
earthquake. Contact local utilities for code requirements in your area or call: 1-866-766-7489 and request
instructions.
The Commonwealth of Massachusetts:
1) The outdoor units (OD) can only be used if they are for summer use only.
2) The water heater can be used for hot water only and not in a combination of domestic and space
heating.
For Venting Manufacturers Requirements, see websites or phone numbers listed below: