Inputs And Outputs; Rotary Switch - Configuration Of Inputs And Outputs - Assa Abloy uP N5951 Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Inputs and outputs

Rotary switch – configuration of inputs and outputs
Position
Function
1
Handle control/monitoring
2
Cylinder handle control
3
Access control/cylinder handle control External release
4
Access control motorised lock
5
Access control/cylinder motorised lock External release
6
Cylinder/BMA motorised lock
7
Cylinder motorised lock
8
No function assigned
Tab. 1: Configuration of inputs via the rotary switch (access control)
Position
Function
1
Handle control/monitoring
2
Cylinder handle control
3
Access control /
cylinder handle control
4
Access control motorised lock
5
Access control /
cylinder motorised lock
6
Cylinder/
BMA motorised lock
7
Cylinder motorised lock
8
No function assigned
Tab. 2: Configuration of outputs via the rotary switch (access control)
*1)
External monitoring contact (or insert monitoring contact bridge)
EN
40
Inputs
IN1
IN2
External release
External door contact
External release
External door contact
External door contact
External release
External door contact
External door contact
External release
External door contact
External release
External door contact
Outputs
REL1
REL2
Locked
Internal door handle
operated
Locked
Cylinder operated
Locked
Cylinder without internal
door handle
Locked
Internal door handle
operated
Locked
Cylinder without internal
door handle
Locked
Cylinder operated
Locked
Cylinder operated
*1)
*1)
*1)
*1)
*1)
*1)
*1)