Operating Information; List Of Accessories; Scope Of Supply - Weller WFE-P Mode D'emploi

Le système d'aspiration des fumées de soudage
Masquer les pouces Voir aussi pour WFE-P:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
If the extraction performance of a cleaned FE soldering bit is
no longer adequate, the filters must be checked. The prelimi
nary filter can be changed several times before the main fil-
ter has to be replaced.
When original Weller filters are used in the prescribed man-
ner, the service lives of the particulate filter and the wide
band gas filter are designed to be approximately equal.
To change the filters, the two release buttons (3) for the lif-
ting device must be pressed simultaneously. The built-in lif-
ting device lifts up the pump casing (2) and exposes the
main filter cartridge (6). Following this, the main filter car-
tridge and the preliminary filter below it can be replaced wit-
hout the use of tools (see also exploded-view drawing).
Before the new main filter cartridge is fitted it should be
marked with the date of installation. The unit should be
installed in reverse sequence.
Warning:
When inserting filters, take care to follow the correct
sequence and fit them in the appropriate position. The
soiled filters must be treated as hazardous waste.

4. Operating information

The pump casing (2) simultaneously acts as a heat sink and
consequently heats up. Excessive heating is prevented by a
built-in thermal cut-out.
The WFE P soldering fume extraction unit is not suitable for
the extraction of flammable gases.

5. List of accessories

EC1002-1FE
Station, Dial Controlled
EC2002M-FE
Station, Digital
WTCPTFE
Station, Magnastat
EC1201FE
Iron, 42 Watt for EC1002-FE &
EC2002M-FE
TC201FE
Iron, Magnastat 42 Watt for WTCP
Stations
AKFE_
Adapter Kits available for other brand
irons, contact Customer Service
RT-FE
WF1026 Tubing Clear Regular
7 foot Replacement for Irons
WF1026
Tubing, ESD Replacement for Irons
Fume Adaptor Kits
AKFE1-1
Weller:
EC1201A, TC201T, WCC100,
WTL120, W60P, W100P,
WP25P, WP40P, SP23, SP40, SP80,
SPG80, WLC100, WLC200
Pace:
IR-70
Hexacon:
1002PBS, 1002, HTC5500,
HTC5600
Ungar:
UTC100, UTC300, 9931AS, 9931HC
AKFE2
Hakko:
900M, 900L Series Irons,
AKFE3
Weller:
WP25, WP30, WP35
Jensen:
47B723
AKFE4
Ungar:
SL325, SL335, SL345, SL500,
7400, 7500, 5550, 555XR,
555XT Soldering Irons,
2110 Soldering Station
AKFE5
Edsyn:
930 Series Iron
AKFE6
Ungar:
9911AS, 9911 HC, 9941 AS,
UTC200, and 9300 Series
Soldering Irons
AKFE7
Ungar:
40S-MOD, 60S-MOD

6. Scope of supply

The WFE P is equipped with:
1 fine particulate air filter
1 main filter cartridge consisting of Class 3 particulate
filter and gas filter:
50% activated carbon, 50% Purafil
1 mains cable
1 set of operating instructions
1 Safety Information
Illustration: exploded-view drawing - see page 23
Subject to technical alterations and amendments!
English
10

Publicité

Table des Matières
loading