english
Connecting the feed line:
• The connecting adaptor can be turned
in relation to the inflow direction:
- Remove the screws (notice O-ring and
washers of connecting adaptor).
- Place connecting adaptor into posi-
tion.
- Replace the screws and tighten.
• Connect the inlet hose to any adaptor
inlet point by means of a hose clamp
(use the hose connectors supplied with
the unit).
• Check that the unused inlet points are
tightly plugged!
Note:
Shut off condensate drain outlet until the
oil-water separator has been installed and
is ready to be put into service!
3. Waste water outlet:
• Attach the water outlet hoses to the
water outlet and to the service valve of
the ÖWAMAT and lead it to the waste
water connection with a continuous
downward slope.
Please note: the service valve is closed
during operation.
Install a siphon to seal off odours.
. ÖWAMAT with heating (optional)
• Please follow the instructions for
installation and operation of heating
Systems.
• The electrical installation must only be
carried out by suitably qualified and
authorised personnel !
• If the temperature of the medium drops
below approx. 41 °F, the heating will be
switched on automatically.
• When the setpoint temperature of 59
°F is attained, the heating will again be
switched off automatically.
• Built-in overheating protection limits the
temperature of the heating system to a
maximum of 167 °F.
ÖWAMAT 12, 14, 15, 16