Electrical requirements
You can find the identification plate with the electrical
specifications on the underside of the appliance. The
junctionbox must be located within 3 feet of the cooktop
connection. It should be easily accessible for service
purposes.
PD[ PP )LWWLQJ&RQGXLW
PP
DSSUR[ PP
&RQQHFWLRQ
Å-´ %R[
&RQGXLW DSSUR[ IW a PP
Prepare Installation Space
Create the cut-out in the countertop according to the
installation diagram. The angle of of the cut surface to
the countertop must be 90°.
The lateral cut-out edges must be flat in order to ensure
that the retaining springs are well-positioned on the
appliance. With multi-layered countertops, secure strips
laterally in the cut-out if necessary.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat- and water-resistant manner.
Observe minimum distance between device underside
and furniture parts of
/
3
8
The worktop must be reinforced if it is less than 20 mm
thick. Otherwise, it is not stable enough. The reinforced
countertop must support at least 60 kg (weight of
cooktop, cookware and food combined). Reinforcement
material used must be resistant to heat and moisture.
PLQ PP
DLU FOHDUDQFH
" (10 mm).
Power supply
CIT 36 XKB Models...
40 Amp circuit breaker
240 Volt, 3 Wire, 60 Hz
208 Volt, 3 Wire, 60 Hz
All with 39" (1 m) flexible conduit (included)
PP
PLQ PP
PLQ
PP
PLQ PP
PP
[
PLQ
PP
PLQ
PP
PP
7